Multi-Width Shake

DaVinci Multi-Width Shake - Aged Cedar
DaVinci Roofscapes Logo

Rocky Mountain Snow Guards has the best snow guard for your DaVinci Multi-Width Shake roof. For lighter snow loads and lower pitch roofs, we specify our SnowTrapper (ST) snow guards in a traditional “spread” pattern. Snow on steeper pitches with higher loads is effectively held in place with our Everest Guard (EG), Rocky Guard (RG), and Yeti snow guards in our own soldier row pattern. The soldier row is a row of snow guards 12” apart on center horizontally. The steeper the pitch or the higher the snow load, the closer the soldier rows will be to each other vertically. Please check the table below for our exact snow guard and pattern for your DaVinci Multi-Width Shake roof.

See our snow retention products in use on the impressive DaVinci Multi-Width Shake roofs of the Horizon Pass Lodge in this Architectural West magazine article.
 

Roof Type:

Synthetic and Cedar Shingle

Select Type of Installation:

Show Recommendations for a New or Existing Roof?

Recommended Snow Guards:

Ground Snow Load (PSF)Roof Snow Load (PSF)Roof SlopeRecommended Snow FencesRecommended Snow GuardsSnow Guard QuantitySnow Guard Pattern
0-220-15Any Pitch11/SQ

12" Soldier Row on 3rd course of shingles with additional Soldier Rows at intervals not to exceed 120" up the roof.

23-7016-502/12 to 6/1211/SQ

12" Soldier Row on the 3rd course of shingles.  Supplemental rows of snow guards in a 30" vertical x 48" horizontal pattern to 10' from the peak.  Every other row is offset 24" horizontally.

23-7016-50Over 6/12 to 7/1213/SQ

12" Soldier Row on the 3rd course of shingles and every 100" or less to the peak.

23-7016-50Over 7/12 to 10/1214/SQ

12" Soldier Row on the 3rd course of shingles and every 90" or less to the peak.

23-7016-50Over 10/12 to 14/1215/SQ

12" Soldier Row on the 3rd course of shingles and every 80" or less to the peak.

71-12051-1202/12 to 6/1214/SQ

12" Soldier Row on the 3rd course of shingles and every 90" or less to the peak.

71-12051-120Over 6/12 to 7/1216/SQ

12" Soldier Row on the 3rd course of shingles and every 70" or less to the peak.

71-12051-120Over 7/12 to 10/1217/SQ

12" Soldier Row on the 3rd course of shingles and every 60" or less to the peak.

71-12051-120Over 10/12 to 14/1221/SQ

12" Soldier Row on the 3rd course of shingles and every 50" or less to the peak.

Ready to Get Started?

Request a FREE layout and design quote from our snow retention experts.

Request a Free Quote